Paper industry
Recovery and reuse of white-water pulp.
Confirm fibre loading, recycle objectives and downstream water-quality requirements.
Product overview
A product-level view of the equipment duty, process position and functional zones.
The QF series is a combined flotation unit for solid-liquid separation where fine suspended matter has a density close to water. Its treatment scope includes suspended solids, oil and colour-bearing material in wastewater.
A portion of clarified water is recirculated through the dissolved-air system. After pressure release, microbubbles attach to conditioned flocs in the contact zone. The bubble-floc complexes rise in the separation zone, where the surface layer is removed by the skimmer and clarified water leaves through the collection system.
QF model capacities, power, dimensions, weight and construction grades require an approved project data sheet before equipment selection.
For an independent explanation of pressure release, fine-bubble formation and bubble-assisted separation, see the U.S. EPA dissolved air flotation fact sheet (PDF). This historical source supports the stable process principles described above, not current costs or KUOSI performance guarantees.
Receives wastewater and the selected coagulant or flocculant before separation.
Introduces dissolved-air water so released microbubbles can attach to conditioned flocs.
Allows bubble-floc complexes to rise while clarified water remains below.
Moves the floated surface layer into the sludge compartment.
Discharges treated water and returns a selected portion to the dissolved-air system.
Engineering advantages
Evaluate the equipment through operating implications, not decorative feature claims.
The QF arrangement combines contact, flotation, skimming, clarified-water collection and recycle functions in one system.
A portion of the clarified effluent is returned to the dissolved-air system instead of requiring a separate recycle source.
Automatic skimmer timing and travel-switch reversal are available, with a manual mode for special operating conditions.
A dedicated anti-blocking microbubble release device adjusts its flow with dissolved-air pressure.
The unit can be installed at ground level or overhead when the project layout and foundation are designed accordingly.
Site commissioning covers startup, clean-water trial, pressure, skimmer, water-level and shutdown checks.
Applications
Representative wastewater analysis and treatability testing are required before selecting the system for these industries and duties.
Recovery and reuse of white-water pulp.
Confirm fibre loading, recycle objectives and downstream water-quality requirements.
Separation of oil and grease from industrial wastewater.
Provide free and emulsified oil data and confirm whether chemical destabilisation is required.
Removal of colour-bearing matter and impurities from dyeing wastewater.
Bench testing should confirm chemical response and the required clarification duty.
Removal of impurities from tannery wastewater.
Confirm wastewater chemistry, corrosion conditions and the selected pretreatment sequence.
Removal of suspended solids and colour.
Review wastewater variability and treatability before defining the equipment duty.
Solid-liquid separation after chemical treatment for heavy-metal removal.
The chemical treatment basis, target metals and achievable result require laboratory confirmation.
Separation of sludge and suspended material after biological treatment.
Provide biological solids characteristics, flow variation and the required downstream route.
Performance
The table shows operating references. They are not guaranteed project performance or a substitute for an approved model data sheet.
| Parameter | Value / range | Engineering note |
|---|---|---|
| Dissolved-air working pressure | 0.3-0.5 MPa | Confirm the final pressure setpoint and equipment rating for the selected project. |
| Released bubble diameter | 20-30 μm | This range applies under reduced-pressure release; project performance remains wastewater-specific. |
| Clarified-water recycle | 30% of wastewater flow reference | Use this as a general control reference and adjust the actual amount to influent SS. |
| Flocculation reaction time | About 5 minutes | Determine the optimum time, dose and response through laboratory testing. |
| Wastewater pH during operation | 7.5-8.5 reference | Final chemical conditions depend on actual wastewater and treatment targets. |
| PAC / PAM reference | PAC 20-50 mg/L; PAM about 1/10 of PAC | These are preliminary references only. Coagulant and flocculant selection and dose must be established by testing. |
Working principle
The sequence runs from chemical conditioning and dissolved-air recycle through flotation, skimming and clarified-water discharge.

This equipment photo identifies the recycle pump and connected piping. It is not a process diagram or a model-specific data sheet.
Wastewater is mixed with the selected treatment chemicals under conditions established from wastewater testing.
A portion of clarified water is pressurised with air in the dissolved-air system.
The recycle stream is released into the contact zone, forming microbubbles that attach to flocs.
Bubble-floc complexes rise to the surface while clarified water remains in the lower layer.
The skimmer moves floated material into the sludge compartment.
Clarified water leaves through the collection system, with a selected portion returned for dissolved-air generation.
Equipment video
See an installed dissolved air flotation system operating in an on-site wastewater separation setting. The footage complements the process explanation on this page by showing the equipment at working scale and the practical arrangement around the flotation vessel. It is presented as an operating reference rather than a quantified treatment result. Effluent quality, solids loading, recycle conditions and chemical demand must still be confirmed from the actual wastewater and approved design basis.
System configuration
The DAF duty combines conditioning, dissolved-air generation, pressure release, flotation, surface skimming, clarified-water collection and recycle.

Final interfaces and included equipment are defined by the agreed project scope.
Confirm pH, chemical selection, dose, mixing and flocculation time from representative wastewater testing.
Set the recycle flow and dissolved-air pressure from influent SS, hydraulic duty and verified treatment response.
Define automatic skimming time and sludge-compartment routing for the actual floated-solids loading.
Adjust the operating level so the surface layer can enter the sludge outlet without excessive water carryover.
Confirm ground-level or overhead placement, access, lifting and the required foundation arrangement.
Locate the electrical box for safe access and protect it from moisture, dampness and corrosive gases.
Wastewater is adjusted and mixed with the selected coagulant or flocculant.
Conditioned wastewater meets the pressure-released dissolved-air recycle stream.
The working pump, ejector, dissolved-air tank, air supply and release device prepare the recycle stream.
Attached solids rise and separate from the clarified lower water layer.
The skimmer transfers floated material to the sludge compartment.
Collected water is discharged, with a selected portion returned to the dissolved-air system.
Main equipment
Supporting / optional equipment
Technical data
These values are operating references, not a QF model comparison. Rated capacity, power, dimensions, weight, control-system specification and construction grade require an approved project-specific data sheet.
Scroll horizontally to review all technical fields on smaller screens.
| Operating item | Reference value | Project confirmation |
|---|---|---|
| Dissolved-air pressure | 0.3-0.5 MPa | Confirm the selected operating setpoint and equipment rating. |
| Released bubble diameter | 20-30 μm | Confirm performance with the selected release device and wastewater. |
| Clarified-water recycle | 30% of wastewater flow reference | Adjust from influent SS and verified flotation response. |
| Flocculation time | About 5 minutes | Determine optimum time and mixing conditions through testing. |
| Concrete foundation allowance | (L + 500) × (B + 500) | Use the approved equipment dimensions and include separate equipment foundations where required. |
| Operating water level | 1-2 cm below the scum outlet | Commission the level to avoid poor skimming or excess water in the sludge compartment. |
| Dissolved-air stabilisation | Approximately 10 minutes during clean-water trial | Verify stable dissolved-air water before introducing wastewater. |
Equipment selection
Selection begins with wastewater flow, influent characteristics, treatment target and verified coagulation and flocculation response.
Identify the production process and the upstream and downstream treatment steps.
Provide average, peak and batch flow conditions together with the intended operating schedule.
Share representative SS, oil and grease, colour, pH and other relevant wastewater analysis.
Define the required clarification duty and the next process or discharge route.
Provide jar-test or site-test results for coagulant, flocculant, pH and flocculation time when available.
Confirm the sludge storage, transfer and downstream dewatering arrangement.
Confirm footprint, elevation, lifting access, foundation, climate, corrosion conditions, voltage and control interfaces.
Manufacturing & installation evidence
These approved images show KUOSI DAF equipment and installation contexts. They are not presented as quantified customer case studies.
Registered DAF media showing outdoor, sheltered and side-view installation contexts.



Engineering support
Support is presented as a practical engineering workflow, without unverified company statistics or outcome claims.
Review the available flow, water-quality and treatment-target data before equipment selection.
Define the laboratory or site testing needed to confirm pH, chemical selection and flocculation response.
Evaluate hydraulic duty, recycle requirements and operating schedule from confirmed project inputs.
Define dosing, dissolved-air, skimming, sludge, clarified-water and control interfaces.
Provide the applicable clean-water trial, pressure, water-level, skimmer and startup checks for the agreed scope.
Technical FAQ
The answers separate general selection logic from the values that require a project-specific technical review.
The KUOSI QF system is a horizontal-flow solid-liquid separation unit. It releases dissolved air into conditioned wastewater so microbubbles attach to flocs, lift them to the surface for skimming and leave clarified water below.
Conditioned wastewater enters the contact zone and meets pressure-released dissolved-air recycle water. Bubble-floc complexes rise in the separation zone, the skimmer transfers floated material to the sludge compartment, and clarified water is discharged with a portion returned to the dissolved-air system.
Applications include paper white-water recovery, oil-containing wastewater, leather, textile dyeing, pharmaceutical wastewater, heavy-metal treatment and post-biological solid-liquid separation. Final suitability still depends on representative wastewater data and testing.
The working-pressure reference is 0.3-0.5 MPa. The final operating setpoint and equipment rating must be confirmed for the selected project and release device.
Use 30% of wastewater flow as a general dissolved-air-water reference, then determine the actual amount from influent suspended solids. It is not a universal fixed ratio.
PAC and PAM references, pH adjustment and an approximately five-minute flocculation reaction provide a preliminary basis. Chemical type, dose, pH and reaction time must be selected from actual wastewater testing rather than applied as guaranteed universal settings.
Provide average and peak flow, wastewater source, SS, oil and grease, colour, pH, treatment target, chemical-test results, operating schedule, sludge route, site utilities and installation constraints. A rated QF model-capacity table must be confirmed for the project.
Installation checks include a level foundation, debris removal, pump and transmission checks, correct motor rotation, skimmer and agitator checks, clean-water trial operation, dissolved-air pressure verification, water-level adjustment and protection of the electrical box from moisture and corrosive gases.
Engineering inquiry
Share your wastewater flow, influent analysis, treatment target, chemical-test results and site conditions. KUOSI can use the available data to evaluate the appropriate DAF duty and system configuration.